Ash remover WX803

Product features: WX-803 ash remover is suitable for ash removal after alkali etching of aluminum alloy, providing a clean and tidy surface for the material before peeling. The use of WX-803 ash remover can remove the ash film and impurities on the surface of the workpiece after whitening, and increase the cleanliness of the surface of the material. 2. using parameters Building bath proportion: 10-20% Processing temperature: 25-35 Processing time: 10-20 seconds Control concentration: 50-75 Note: Due to the differences in materials, processes and equipment of each customer, the above data are for reference only, and the actual production shall prevail. 3. detection method Acidity: take 10ml of bath solution into conical flask, add 3-4 drops of P.P indicator, and then titrate the color from colorless to pink with 1mol/L NaOH, which is the end point. At this time, the consumption of 1mol/L NaOH ml number, that is, the acidity of the bath. 4. Trough Material PP/PVC tanks shall be used. 5. supplement method Supplementary amount = 7.46 * V groove volume (L)* rising value/100 (note: rising value = best value-analysis value) 6. slot change cycle For 500L tank, under the condition of continuous production and normal supplement of chemicals, if the treatment area reaches 4000-5000m ², please replace the tank liquid (this data is for reference only, and the actual production material depends on the site).

Keywords: water-based epoxy resin/water-based acrylic resin/water-based polyester resin.

Product Classification:

Product Details


Product characteristics
WX-803 ash remover is suitable for the ash removal of aluminum alloy after alkali etching, providing a clean and tidy surface for the material before peeling. The use of WX-803 ash remover can remove the ash film and impurities on the surface of the workpiece after whitening, and increase the cleanliness of the surface of the material.

Using Parameters                                                            

Building bath proportion: 10-20%

Processing temperature: 25-35

Processing time: 10-20 seconds

Control concentration: 50-75
Note: Due to the differences in materials, processes and equipment of each customer, the above data are for reference only, and the actual production shall prevail.

Detection method

Acidity: take 10ml of bath solution into conical flask, add 3-4 drops of P.P indicator, and then titrate the color from colorless to pink with 1mol/L NaOH, which is the end point. At this time, the consumption of 1mol/L NaOH ml number, that is, the acidity of the bath.

Trough material

PP/PVC tanks shall be used.

supplementary method

Supplementary amount = 7.46 * V groove volume (L)* rising value/100 (note: rising value = best value-analysis value)

Groove change cycle

For 500L tank, under the condition of continuous production and normal supplement of chemicals, if the treatment area reaches 4000-5000m ², please replace the tank liquid (this data is for reference only, and the actual production material depends on the site).